5/6/2019
Posted by 
Manual Minisplit York Gz-12a-e1 Average ratng: 5,9/10 9763 reviews
Installation & Operations Manual
ENGLISH

View and Download York Y7USC12-2R installation & operation manual online. Y7USC12-2R Air Conditioner pdf manual download. Also for: Y7usc12-6r, Y7uec12-6r, Y7ush12-6r, Y7usc18-6r, Y7ush18-6r.

  1. Find great deals on eBay for York Remote Control in TV Remote Controls. Shop with confidence.
  2. Installation & Owner’s Manual MODELS MINISPLIT RLCA-RLHA 07-30 HIGH WALL AIR CONDITIONER The units comply with one or more of the following marks.
Installation ................................ 3
Manual mini split carrier
Maintenance ............................ 7
Instalación ................................ 9
Mantenimiento .......................... 14
Por favor llame al
o mande un correo a
EL FABRICANTE SE RESERVA EL
Carrier
DESCONTINUAR LAS

Manual Mini Split Carrier

SIN INCURRIR EN OBLIGACIONES
Gracias por seleccionar el aire acondicionado YORK.
Por favor guarde este Manual de Propietario para las
Lea las instrucciones de Manera cuidadosa así como
Manual de
Funcionamiento
York
Y7USC12-6R

Mini Split York Monterrey

Y7USH12-6R
Y7USH18-6R

Advertisement

Related Manuals for York Y7USC12-2R

  • Air Conditioner York Y34 Technical Manual
    Millennium single package rooftop units 25, 30, & 40 ton (96 pages)
  • Air Conditioner York YCJF24 Technical Manual
    Split-system air conditioners 14.5 seer – r-410a 2 thru 5 nominal tons, 1 phase (30 pages)
  • Air Conditioner York YCJF24 THRU 60 Technical Manual
    Split-system air conditioners 14.5 seer – r-410a (28 pages)
  • Air Conditioner York YCJD18 THRU 60 Technical Manual
    Split-system air conditioners 13 seer – r-410a – 1 phase (18 pages)
  • Air Conditioner York YCJD18 Technical Manual
    Split-system air conditioners 13 seer – r-410a (18 pages)
  • Air Conditioner York YCJD18 Technical Manual
    Lx series split-system air conditioners 13 seer – r-410a – 1 phase 1.5 thru 5 nominal tons models: ycjd18 thru 60 (26 pages)
  • Air Conditioner York YHJD18 THRU 60 Technical Manual
    (38 pages)
  • Air Conditioner York Alaska Y9USC05-5A-F User Manual
    Alaska room air conditioner (16 pages)
  • Air Conditioner York YDS03U-011bW-05117 Owner's Manual
    Digital scroll central air-conditioner (indoor unit) (20 pages)
  • Air Conditioner York YEHNZH018BAMKAFX User Manual
    Mini-split air conditioner (27 pages)

Summary of Contents for York Y7USC12-2R

  • Page 1: Table Of Contents

    Y7USC12-6R ESPECIFICACIONES DE DISENO Y7UEC12-6R SIN INCURRIR EN OBLIGACIONES Y7USH12-6R Gracias por seleccionar el aire acondicionado YORK. Y7USC18-6R Por favor guarde este Manual de Propietario para las Y7USH18-6R Instrucciones y su Garantía. Lea las instrucciones de Manera cuidadosa así como...
  • Page 2: Important Safety Instructions

    Electrical Requirements & Safety Precautions • Do not operate this air conditioner • Do not introduce objects in the air Warning without proper time delay circuit discharge area. This could cause protection. Refer to serial plate for permanent damage to your unit. proper power supply requirements.
  • Page 3: Installation

    Installation Cleaning the Air Filter Tools Needed Removing the Chassis 1. Remove the two (2) shipping Clean the filter every two weeks screws from the rear bottom side 1. Turn Master Control to OFF. of the cabinet. These shipping 2. Remove the air filter by opening the screws may be discarded.
  • Page 4 Thru-the-Wall Installation Through-the-wall Installation Installing the Chassis into the Cabinet 3. Install the finished frame in the wall Slide the chassis into the opening square and level, nail or This air conditioner is designed as a cabinet. screw it securely to the wall and slide-out type chassis, making it possible place the cabinet into the framed Replace the two antitheft screws...
  • Page 5 Wood frame Fig. 1 1” wood screws Cabinet Bottom Bar Interior wall Decorative Front Minimum 1x6 wood support (nailed or screwed to wood frame) 2” Wood frame 1 1/2” space 1 1/4” space Brick veneer Lintel angle Caulking Fig. 2 Flashing (drip rail) Side louvers Wood filler strip...
  • Page 6: Operation

    Operation Power Control Fan Speed Control - Electronic Control (Cooling Only) High, The Power Control turns the unit on and off. Medium, Low and Auto Set Temperature/ Timer Display The settings are adjusted with the Fan Speed Shows the set temperature when the unit is in Control, each time the button is depressed it operation and hours when the timer is being changes the setting.
  • Page 7: Maintenance

    Troubleshooting Air Conditioner Remote Control The functions work the same as your air conditioner’s touch controls. Batteries: Remove the cover on the back of the remote controller and insert the batteries with the (+) and (-) poles pointing in the proper direction. 1.5V IEC R03 '...
  • Page 8: Instrucciones Importantes De Seguridad

    Instrucciones importantes de seguridad • Use solamente conductores de cobre y Precauciones de Seguridad Adicionales Advertencia fusibles de calibre y capacidad adecuada. • No corte, modifique ni retire ningún • No modifique el cordón ni el enchufe del pedazo de poliestireno expandido extremo.
  • Page 9: Instalación

    Instalación Herramientas Necesarias Desmontaje del Chasis Retire los dos (2) tornillos de embarque* del costado inferior trasero del gabinete. Retire los dos (2) tornillos antirrobo de ambos lados delanteros inferiores del gabinete. CONSERVE ESTOS TORNILLOS, ellos serán usados posteriormente Desarmador en la instalación.
  • Page 10 Instalación Empotrado en la Pared 3. Instale el marco terminado en la Instalación Empotrado en la Pared Instalación del Chasis cavidad mural de manera que quede en el Gabinete Este aire acondicionado sido a escuadra y nivelado, luego clávelo o diseñado como un chasis deslizable, Deslice el chasis hacia el interior del atorníllelo firmemente en la pared e...
  • Page 11 Marco de madera Fig. 1 Tornillos de madera de 1” Gabinete Barra inferior Pared Panel decorativo delantero Soporte de madera de por lo menos 1 x 6 (clavado o atornillado en el marco de madera) Marco de madera de 2' por todo el rededor Fig.
  • Page 12: Funcionamiento

    Funcionamiento Control de Alimentación Control Electrónico (Enfriamiento Solamente) Este botón pone en marcha y apaga el aire acondicionado. Indicador de Temperatura de Ajuste/Temporizador El indicador muestra la temperatura de ajuste cuando el aire acondicionado está en funcionamiento y las horas cuando se ha activado el temporizador. EL INDICADOR LA TEMPERATURA SOLAMENTE...
  • Page 13 Funcionamiento Limpieza del Filtro del Aire Control de la Velocidad del Control del Temporizador Ventilador – Limpie el filtro cada dos semanas Alta, Mediana, Baja y (El temporizador puede ser ajustado ya sea Automática para encender o apagar el aire 1.
  • Page 14: Mantenimiento

    Servicio Para ahorrar tiempo y dinero, verifique lo siguiente antes de llamar a un centro de servicio autorizado. Problema Causa Posible Soluciones El aire acondicionado no funciona • El enchufe mural está desconectado. Inserte bien el enchufe en el tomacorriente mural. •...
  • Page 16 23-11-2263N-003...